Skip to content
📞 1300 987 789 | sales@petroindustrial.com.au
📞 1300 987 789 | sales@petroindustrial.com.au

Description

GRACO LD Series Electronic Dispense Meters and Control Valve Range

For use with Petroleum-, synthetic-based oils and Anti-freeze.  Typical Application are Automotive and Heavy-duty dealerships, Fast lube centres, Fleet service facilities, Service shops and In-plant.  For indoor use only.

FEATURES:

  • Manual and Preset Dispense.
  • Dispenses in gallons, quarts, pints and liters.
  • Easy to read LCD display with durable switches for long life.
  • Rugged engineered material for superior impact resistance and long life.
  • Ergonomically-designed handle for optimum comfort.
  • Standard rigid extension kit and automatic thermal compensating nozzle.
  • Optional extensions available.

PRODUCT RANGE:

Code

Description

LDM5 Manual Dispense Meters

255751

1/2 in npt(f) swivel, flexible extension and automatic nozzle for oil and anti-freeze.

256215

1/2 in npt(f) swivel, rigid extension, trigger guard/boot and automatic nozzle for oil and anti-freeze.

258693

1/2 in npt(f) swivel, flexible extension, trigger guard/boot and automatic nozzle for oil and anti-freeze.

LDP5 Preset Dispense Meters

255277

1/2 in npt(f) swivel, flexible extension and automatic nozzle for oil and anti-freeze.

256216

1/2 in npt(f) swivel, rigid extension, trigger guard/boot and automatic nozzle for oil and anti-freeze.

258694

1/2 in npt(f) swivel, flexible extension, trigger guard/boot and automatic nozzle for oil and anti-freeze.

 

SPECIFICATIONS:

  • Flow Range(1): 0.1 - 5 gpm (0.4 - 19 lpm)
  • Maximum Working Pressure: 1000 psi (69 bar)
  • Units of measure: Quarts, pints, gallons, liters (factory set to quarts)
  • Weight: 3 lb (1.36 kg)
  • Inlet: 1/2 in npt
  • Outlet: 1/2 in npt
  • Operating Temperature Range: 32 - 120º F (0 - 48.8º C)
  • Storage Temperature Range: -30 - 120º F (-34.4 - 48.8º C)
  • Battery: 9 volt alkaline
  • Battery Life: one year
  • Wetted Parts: sst, nitrile rubber, zinc, cs, lcp
  • Meter Pressure Loss(1): 90 psi (6.2 bar) @ 5 gpm (19 lpm)
  • Accuracy(2): ±0.5%
  • Dimensions (without extension): 11 in L x 3.25 in W x 3.25 in H (28 cm L x 8.3 cm W x 8.3 cm H)
  • Maximum Totalizer: 999,999 gallons or liters
  • Maximum Recorded Dispense: 999.9 Units (LDP5 only)
  • Warranty: Two Years
  • Instruction Manual: 312668

(1) Tested in 10W oil at 70ºF. Flow rates vary with fluid pressure, temperature, viscosity, inlet fitting and nozzle type.

(2) @ 2.5 gpm (9.5 lpm) @ 70º F (21º C) with 10 wt. oil and 1 gal (3.8 l) dispensed.

May require re-calibration. Out-of-box accuracy ±1.25%. Not recommended for in-line installation.