Skip to content
đź“ž 1300 987 789 | sales@petroindustrial.com.au
đź“ž 1300 987 789 | sales@petroindustrial.com.au

Description

PETRO 4 Litre Closed Circuit Sampler

The PETRO 4 Litre Closed Circuit Sampler has been designed to overcome problems that impact the accuracy of sampling. Its design ensures that there is no contamination to the sample during transfer to the Sampler. It also removes the risk of fuel spillage and contact with operations staff.

FEATURES:

  • Clear glass tube fitted to a white epoxy coated conical base (to assist in the detection of dirt and water).
  • Hinged vented cover (to assist with easy cleaning of the Sampling equipment).
  • Gravity drainage is possible.

BENEFITS:

  • No fuel spillage.
  • No sample contamination.
  • Easy to clean.
  • Easy detection of dirt and water.
  • Full visual aviation fuel checking a closed system.
  • Direct drainage under gravity.
  • Water detection, density and temperature checking options.

ORDERING INFO:

Description

BSPP Threads

NPT Threads

Basic Model

6007233001

6007233021

Basic Model +Internal Velcon Hydrokit Fitting

6007233002

6007233026

Basic Model + Internal Shell Water Detector Fitting

6007233003

6007233025

Basic Model + Internal Velcon Hydrokit Fitting + Hydrometer and Thermometer Tubes

6007233004

6007233024

Basic Model + Internal Shell Water Detector Fitting + Hydrometer and Thermometer Tubes

6007233005

6007233022

Basic Model + Hydrometer and Thermometer Tubes

6007233016

6007233023

Adds External Shell Water Detector Fitting

6007233212

6007233213

Adds External Velcon Hydrokit Fitting

6007233203

6007233204

Capsule Catcher for retro fit

6007233264

6007233264

Adds 3/8” Apollo Spring Close Fill Valve

06076502P01

0607650201

 

DESCRIPTION & OPERATION:

The Aljac CCS consists of a clear glass tube fitted to a white epoxy coated conical base to assist in the detection of dirt and water, and with a hinged vented cover. The base incorporates a tangential inlet port to promote vortexing of the incoming fuel, and a close coupled Stainless Steel drain valve.

The inlet port should be connected to the sample points using small bore tubing (typically 10mm diameter), and we recommend fitting spring close inlet valves close to the CCS to control the filling operation, which we can also supply. The drain port should be connected into the hydrant dispenser dump tank, depot product recovery system, or storage tank using 20mm inside diameter pipework. It is recommended that the CCS is located such that gravity drainage is possible. If not, we are able to supply a rotary pump and non return valve to drain the CCS.

When fuel is drawn into the CCS under pressure from the sample points the tangential inlet port promotes vortexing of the incoming fuel. This concentrates any contamination in the centre of the base, making detection very easy. After the fuel has been visually inspected the drain valve is opened to release the sample. Internal cleaning of the Aljac CCS is easily accomplished through the hinged lid.

A number of options are also available.

Hydrometer and thermometer pockets for density and temperature checks can be provided in conjunction with a removeable inner lid. It is also possible to carry out the Shell Water Detector or Exxon Hydrokit test on the fuel sample using an option which can either be fitted to the inner lid (internal), or to a self sealing valve in the inlet port (external). The Aljac CCS is available with BSPP or NPT threads.

THE CAPSULE CATCHER:

Our Sampler is fitted with a Capsule Catcher inside the drain valve. It prevents any SWD capsules which have been inadvertently dropped into the sampler from passing into the drain pipework.

It does so without disrupting the vortex flow pattern of fuel entering the sampler, and also allows the sampler internals to be easily cleaned.

The Capsule Catcher can also be retro fitted to existing Aljac Samplers.

EXTERNAL SWD FITTING OPERATION:

The External SWD fitting was designed to allow the SWD test to be carried out without opening the sampler lid and so exposing the fuel sample to possible contamination. The External SWD is fitted to the inlet connection of the sampler and incorporates a piston valve. When the assembled syringe/capsule is inserted into the External SWD Fitting the action of doing so causes the front edge of the capsule to push open the piston valve, and allows fuel to flow to the capsule, as shown below. The syringe can be operated as normal to draw fuel through the capsule.

SPECIFICATIONS:

  • Working Capacity: 4 Litres.
  • Materials: Borosilicate glass tube, cast Aluminium base and upper section, base white epoxy lined internally.
  • Connections: Inlet 3/8” BSPP or NPT female threaded, outlet 1” BSPP or NPT female threaded.
  • Mounting Holes: M12 female threaded.
  • Overall Dimensions: 405mm high (lid closed), 275mm wide (with SWD fitting), 267mm deep.
  • Nett Weight: 5 Kg (empty).
Contact PETRO industrial's team of bulk fuel storage and dispensing specialists for more information today!